nealogo tagline max (322 x 25)

ENVIRONMENT INFORMATION / ENERGY CONSERVATION / ENERGY LABELLING SCHEME

Contact Us



Tick Rating

The Tick Rating is defined as follows:

Air-conditioners 

Type
COP 100%1 (W / W)
No. of Ticks
0
1
2
3
4
Casement, window, single-split (non-inverter)
COP100% < 2.5
2.78 > COP100% > 2.5
3.2 > COP100% > 2.78
COP100% > 3.2
N/A
Multi-split (non-inverter)
COP100% < 2.64
2.92 > COP100% > 2.64
3.34 > COP100% > 2.92
COP100% > 3.34
N/A
Split type (inverter)2
  • COP100%
  • Weighted COP 3



N/A
Weighted COP
< 2.64



N/A
2.92 > Weighted COP > 2.64



N/A
3.34 > Weighted COP > 2.92



COP100% > 3.06
Weighted COP
> 3.34



COP100% > 3.34
Weighted COP > 3.76

1
COP 100% is defined as the ratio of total cooling capacity to effective power input at full load cooling capacity
2 For split (inverter) type air-conditioners, the model shall meet both the minimum COP 100% and weighted COP
3 Weighted COP = 0.4 x COP 100% + 0.6 x COP 50%

Refrigerators

Type
Annual Energy Consumption (AEC) in kWh
No. of Ticks
0
1
2
3
4
Without freezer
AEC > (368 + 0.892 x Vadj tot4)
[(368 + 0.892 x Vadj tot) x 0.86] < AEC < (368 + 0.892 x
V adj tot)
[(368 + 0.892 x Vadj tot) x 0.74] < AEC < [(368 + 0.892 x
V adj tot) x 0.86]
[(368 + 0.892 x Vadj tot) x 0.64] < AEC < [(368 + 0.892 x
Vadj tot) x 0.74]
AEC < [(368 +
0.892 x
Vadj tot) x 0.64]
With freezer
AEC > (465 +
1.378 x Vadj tot)
[(465 + 1.378 x
Vadj tot) x 0.77] < AEC < (465 + 1.378 x Vadj tot)
[(465 + 1.378 x
Vadj tot) x 0.593] < AEC < [(465 + 1.378 x Vadj tot
x 0.77]
[(465 + 1.378 x
Vadj tot) x 0.457] < AEC < [(465 + 1.378 x
Vadj tot) x 0.593]
AEC < [(465 + 1.378 x
Vadj tot) x 0.457]
With freezer ,
through-the -
door
ice dispenser 5
AEC > (585 +
1.378 x Vadj tot)
[(585 + 1.378 x
Vadj tot) x 0.77] < AEC
<
(585 + 1.378 x
Vadj tot)
[(585 + 1.378 x
Vadj tot) x 0.593] < AEC
<
[(585 + 1.378 x
Vadj tot) x 0.77]
[(585 + 1.378 x
Vadj tot) x 0.457] < AEC
<
[(585 + 1.378 x
Vadj tot) x 0.593]
AEC < [(585 + 1.378 x
Vadj tot) x 0.457]


4 Vadj totis defined here

5 'Through-the-door ice dispenser' means an automatic ice maker coupled with a device that deliveries ice on demand externally through a door

Clothes Dryer

Type
Energy Consumption (EC) per wash in kWh
No. of Ticks
0
1
2
3
4
All clothes dryers
EC > [Rated Capacity6 ]
[Rated Capacity x 0.83] < EC < [Rated Capacity]
[Rated Capacity x 0.67] < EC < [Rated Capacity x 0.83]
[Rated Capacity x 0.50] < EC < [Rated Capacity x 0.67]
EC < [Rated Capacity x 0.50]


6 Rated Capacity means the mass in kilograms of a particular type of dry textiles which, according to the instructions of the manufacturer of the clothes dryer, can be treated in a particular drying programme suitable for drying the particular type of dry textile.

Top


 

Copyright © 2002 National Environment Agency. All rights reserved. Privacy Policy.

NEA Call Centre Hotline: 1800-CALL NEA (1800-2255 632) / Fax: 62352611 / Enquiry Email: Contact_NEA@nea.gov.sg
Dial-a-weather Hotline: 65427788 / Weather Fax-on-demand: 65427789
Members of the media can reach us at media@nea.gov.sg